Evolve EVBF Anleitung zur Fehlerbehebung

Stöbern Sie online oder laden Sie Anleitung zur Fehlerbehebung nach Wasserspender Evolve EVBF herunter. Evolve EVBF Troubleshooting guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Evolve Series

Evolve Series® Water FiltersFor Models:• EVFE• EVS• EAG• EACG• EVBF• EVBF-AN

Seite 2 - TABLE OF CONTENTS

10 START-UP INSTRUCTIONS:FLUSHING OF SYSTEM:To flush the system of any debris and air after installation is complete, please perform the following ste

Seite 3

11 OPERATING DISPLAYS AND INSTRUCTIONS:The air sulfur and air iron filter systems look and function much like any backwashing whole house filter; howe

Seite 4 - BYPASS VALVE:

4. MANUAL REGENERATION: Sometimes there is a need to regenerate before the control valve calls for it. This may be needed if a period of heavy water

Seite 5 - INSTALLATION:

131. Check the media height by shining a flashlight through the tank to see the height of the mineral. If the level is not seen, the top fill plug wi

Seite 6 - (Air charge

14 PROBLEM CAUSE CORRECTION 1. No display on PC board A. No power at electric outlet A. Repair outlet or use working outlet B. Control valve pow

Seite 7 - ASSEMBLY

15 7. Control valve does not regenerate automatically but does when the correct button(s) is depressed and held. For timeclock valves the buttons ar

Seite 8 - PROGRAMMING PROCEDURES:

TROUBLESHOOTING GUIDE cont’d:16 12. Control valve fails to draw in regenerant A. Injector is plugged A. Remove injector and clean or replace B. F

Seite 9

17 PROBLEM CAUSE CORRECTION 15. E2, Err – 1002, Err – 102 = Control valve motor ran too short and was unable to find the next cycle position and

Seite 10 - START-UP INSTRUCTIONS:

18 PROBLEM CAUSE CORRECTION 19. Err – 1007, Err – 107, Err - 117 = MAV/ SEPS/NHBP/AUX MAV valve motor ran too short (stalled) while looking for

Seite 11 - DEALER NA

REPLACEMENT PARTS:2713546FRONT COVER AND DRIVE ASSEMBLYItem No. Part No. Description Qty.1CV3367-01-A Black cover 1CV3367-01-WR-A Gray cover 12 CV31

Seite 12 - BATTERY REPLACEMENT

TABLE OF CONTENTSPreinstallation Instructions for Dealers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Bypass Valve . . . . .

Seite 13 - FOR ACID NEUTRALIZERS:

2023458677911314101112NOTE: Not available on 1¼ " valve.REPLACEMENT PARTS:PISTON ASSEMBLYItem No. Part No. Description Qty.1CV3005 1”

Seite 14 - TROUBLESHOOTING GUIDE:

REPLACEMENT PARTS:BYPASS VALVE Item No. Part No. Description Qty.1 CV3151 Nut, 1” quick connect 22 CV3150 Split ring 23 CV3105 O-ring 215 24 CV3145

Seite 15 - PROBLEM CAUSE CORRECTION

22INJECTOR ASSEMBLIESItem No. Part No. Description Qty.1 CV3176 Injector cap 12 CV3152 O-ring 135 13 CV3177-01 Injector screen 14 CV3010-1Z Inject

Seite 16 - TROUBLESHOOTING GUIDE cont’d:

DRAIN LINE ASSEMBLY 3/4”Item No. Part No. Description Qty.1 CH4615 Elbow locking clip 12 CPKP10TS8-BULK Optional insert, 5/8” tube 13 CV3192 Option

Seite 17

WATER METER & METER PLUGItem No. Part No. Description Qty.1 CV3151 Nut, 1” QC 12 CV3003 Meter assembly, includes items 3 & 4 13 CV3118-01

Seite 18

REPLACEMENT PARTS:25CHLORINE TANK ASSEMBLYItem No. Part No. Description Qty.1 CH4600-50 474 safety float valve 12 CH4640-32 474 float assembly 13 CH

Seite 19 - REPLACEMENT PARTS:

1” PVC MALE NPT ELBOWItem No.Part No. Description Qty.CV3007 1” PVC male NPT elbow assembly 21 CV3151 Nut, 1” quick connect 22 CV3150 Split ring 23

Seite 20

271-1/4” & 1-1/2” PVC SOLVENTItem No.Part No. Description Qty.CV3007-07 1-1/4” & 1-1/2” PVC solvent assembly 21 CV3151 Nut, 1” quick connect

Seite 21

28 SPECIFICATIONS:SULFUR AND IRON AIR FILTERSMineral Type Catalytic Carbon Catalytic Carbon Catalytic Carbon Birm Birm BirmAmount (Cu Ft) 1.0 1

Seite 22

29ACID NEUTRALIZERSBACKWASHING FILTERSMineral Type Calcite or Mix Calcite or Mix Calcite or Mix Calcite or Mix Calcite or Mix Calcite or MixAmou

Seite 23

PREINSTALLATION INSTRUCTIONS FOR DEALERS:3The manufacturer has preset the water treatment unit’s sequence of cycles and cycle times.The dealer should

Seite 24

Evolve Series® Water Conditioner Limited WarrantyCongratulations. You have purchased one of the  nest water treatment systems available. In the unlik

Seite 25

31MANUAL REGENERATIONNOTE: For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regeneration. If you

Seite 26

Manufactured exclusively for Evolve Series Dealers at:1900 Prospect Court • Appleton, WI 54914Phone: 920-739-9401 • Fax: 920-739-9406© 2014 Evolve

Seite 27

4The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs o

Seite 28 - SPECIFICATIONS:

5GENERAL INSTALLATION & SERVICE WARNINGSThe control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There

Seite 29

6 When installing an air regenerating filter the customer may experience, under certain conditions, small amounts of air (cloudy water) at the tap

Seite 30

78. CHECK VALVE: All air systems include an internal check valve and screen assembly as part of the air draw system (see diagram at right). This chec

Seite 31 - QUICK REFERENCE GUIDE:

81. Set time of day: PROGRAMMING PROCEDURES:NOTE: The manufacturer has preset the unit so that the gallons between regenerations will be automaticall

Seite 32 - LIGHT NORMALLY

9 NOTE: This valve has the capability of regenerating up to six times in one day. This can be observed by pressing the CLOCK and + buttons sim

Kommentare zu diesen Handbüchern

Keine Kommentare