Evolve LFM-20 Datenblatt Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
2013
PRODUCT OVERVIEW
Wiring
The LFM-20 is wired as follows:
Black – represents the line input, 120VAC
White – represents the neutral. The LFM-20 and the load must share the same neutral.
Blue 1 (either blue wire) – 24V – 277V input for load switching
Blue 2 (either blue wire) – 24V – 277V output for load switching
The switch also has a green wire which serves as the ground. While there is a yellow wire
present, it is not needed and should be cut and capped with either electrical tape or a wire nut.
In the case of a 3-way or 4-way circuit, traveler wires are not used when building an Evolve
network. Instead, an LFM-20 may be used in conjunction with an LTM-5 to create a wireless,
“virtual” 3-way. See LTM-5 for further details.
Yellow
Status LED
Line
Black
WhiteNeutral
120VAC
Green Ground
Push button to add
node to network
Blue
Blue
LOAD
20 Amps
Maximum
24 to 277V
Seitenansicht 1
1 2